Article Information

Authors:
Alison Lupton-Smith1
Andrew Argent1,2
Peter Rimensberger3
Brenda Morrow1,2

Affiliations:
1School of Child and Adolescent Health, University of Cape Town, South Africa

2Paediatric Intensive Care Unit, Red Cross War Memorial Children's Hospital, South Africa

3Paediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland

Correspondence to:
Alison Lupton-Smith

Email:
aluptonsmith@gmail.com

Postal address:
School of Child and Adolescent Health, Red Cross War Memorial Children's Hospital, University of Cape Town, Klipfontein Road, Rondebosch 7700, South Africa

Dates:
Received: 17 Feb. 2015
Accepted: 14 Apr. 2015
Published: 29 May 2015

How to cite this article:
Lupton-Smith, A., Argent, A., Rimensberger, P. & Morrow, B., 2015, ‘The effects of prone and supine positions on the regional distribution of ventilation in infants and children using electrical impedance tomography’, South African Journal of Physiotherapy 71(1), Art. #237, 5 pages. http://dx.doi.org/10.4102/sajp.v71i1.237

Copyright Notice:
© 2015. The Authors. Licensee: AOSIS OpenJournals.

This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

The effects of prone and supine positions on the regional distribution of ventilation in infants and children using electrical impedance tomography
In This Observational Study...
Open Access
Abstract
Introduction
Research design
   • Research approach
   • Research method
      • Population and sampling
      • Procedure
      • Offline analysis
      • Statistical analysis
Results
   • Ventral and dorsal lung regions
   • Patterns followed
   • The effect of head position
   • The effect of age
Discussion
Acknowledgements
   • Competing interests
   • Authors’ contributions
References
Abstract

Background: Positioning of ill children is often used to optimise ventilation–perfusion matching, thereby improving oxygenation.

Objectives: To determine the effects of supine and prone positions, and different head positions, on the distribution of ventilation in healthy, spontaneously breathing infants and children between the ages of 6 months and 9 years.

Methods: Electrical impedance tomography measurements were recorded from participants in supine and prone positions. Head positions included the head turned to the left and right in supine and prone positions, and in the midline in the supine position. Distribution of ventilation was described using end-expiratory–end-inspiratory relative impedance change.

Results: A total of 56 participants (boys = 31 [55%]; girls = 25 [45%]) were studied. The dorsal lung was significantly better ventilated than the ventral lung (P < 0.001) in both body positions. The majority of participants (83%) had greater ventilation in the dorsal lung in both positions, whilst five participants (10%) demonstrated consistently better ventilation in the non-dependent lung in both positions. Head position had no effect on the distribution of ventilation.

Conclusions: This study demonstrates that the distribution of ventilation in healthy, spontaneously breathing infants and children in supine and prone positions is not as straightforward as previously thought, with no clear reversal of the adult pattern evident.

Introduction

In ill and critically ill individuals, positioning is a non-invasive, inexpensive modality often used to improve oxygenation (Gillies, Wells & Bhandari 2012). Whilst many studies describe the effects of prone or supine positioning on factors such as mortality, arterial oxygenation, functional residual capacity, work of breathing and ventilation–perfusion matching (Curley et al. 2005; Gattinoni et al. 2001; Gillies et al. 2012; Pelosi, Brazzi & Gattinoni 2002), there are a limited number of studies that describe effects on the distribution of ventilation, particularly in infants and children older than 6 months.

To guide clinical practice, an understanding of what occurs under ‘normal’ conditions is essential. Until recently, positioning in the paediatric population has been based on the principle that children preferentially ventilate the non-dependent lung in side-lying positions, as suggested by earlier studies using invasive techniques (Davies et al. 1985; Heaf et al. 1983). This ‘paediatric pattern’ is the opposite of that observed in adults, who preferentially ventilate the dependent lung (West 2011). In adults, the dependent lung regions have a higher compliance, which contributes to the better ventilation in these regions. It was postulated that in infants and children, a greater degree of airway closure occurs in the dependent lung regions as a result of more positive pleural pressures (Davies et al. 1985; Heaf et al. 1983; Mansell, Bryan & Levison 1972; Papastamelos et al. 1995). Recent studies in neonates and infants up to 6 months of age have questioned this principle and suggested that the distribution of ventilation is towards the dependent lung (Frerichs et al. 2003; Hough 2008; Pham et al. 2011; Schibler et al. 2009), which is similar to what is seen in adults.

Lupton-Smith et al. (2013) recently reported the effect of side-lying positions on the distribution of ventilation in healthy, spontaneously breathing children older than 6 months. Response to positioning was found to be highly variable, with no clear ‘paediatric pattern’ of ventilation in either the right or the left lung. Only a few studies have reported the effects of both supine and prone positioning on ventilation distribution in both the ventral and dorsal lung regions in the paediatric population (Pham et al. 2011; Schibler et al. 2009). Although head position in supine and prone positions has been found to have an effect on the distribution of ventilation in neonates and newborns (Heinrich et al. 2006; Hough 2008), the effect in the older paediatric population is still unknown.

The current study aimed to determine the effects of supine and prone positions on the distribution of ventilation in healthy, spontaneously breathing infants and children using electrical impedance tomography (EIT). The effects of age and head position on the distribution of ventilation in prone and supine positions were also examined.

Research design

Research approach

This was a cross-sectional observational study, as described previously (Lupton-Smith et al. 2013).

Research method

Population and sampling

A total of 56 healthy, spontaneously breathing, unsedated infants and children participated in the study. The participants were all between the ages of 6 months and 9 years and were recruited from out-patient clinics and day wards at Red Cross War Memorial Children's Hospital in Cape Town, South Africa. Participants were excluded if they had any respiratory disease (acute, chronic or symptoms in the preceding 6 weeks) or other factors, such as skeletal deformities, neuromuscular disease or cardiac conditions, impacting on respiratory mechanics. The same sample was used to describe the effect of side-lying on the distribution of ventilation (Lupton-Smith et al. 2013).

Ethical approval was obtained from the Human Research Ethics Committee of the University of Cape Town (ref 126/2012). Written informed consent was obtained from the parent or legal guardian of each participant and verbal or written assent was obtained from participants where age appropriate.

Procedure

The distribution of ventilation was measured using an EIT device (Goettingen Goe-MF II EIT System; Viasys/Carefusion, Germany). EIT is an emerging radiation-free, non-invasive imaging tool that is well validated and able to detect regional changes in ventilation in the lungs reliably and reproducibly (Bodenstein, David & Markstaller 2009; De Lema et al. 2008; Frerichs et al. 2007; Reifferscheid et al. 2011; Victorino et al. 2004).

Measurements were recorded in both supine and prone positions, with the head turned to the left and right in each, as well as with the head in midline in the supine position. Participants were first placed in the supine position with the head in midline. Subsequent head positioning was the participant's choice in both supine and prone positions. In both positions, participants lay flat, with their arms extended at their sides. Sixteen neonatal-sized electrodes (Blue Sensor BR-50-K, Ambu, Denmark), connected to the EIT device, were placed around the thorax at the level of the nipple line. EIT scans were generated at 13 scans per second. EIT measurements were recorded for as long as necessary (approximately one minute) to obtain a series of reproducible breaths in the required static position.

Offline analysis

Offline analysis was performed using Auspex Version 1.6 software (Viasys Healthcare, The Netherlands). The data were filtered to eliminate the effect of the heart (Zadehkoochak et al. 1992). A series of five consecutive reproducible breaths was selected for analysis. These were breaths of similar amplitude and without inspiratory or expiratory pauses.

Functional EIT (fEIT) images, similar to the example shown in Figure 1, were generated using the average end-expiratory–end-inspiratory relative impedance change. Calculations were performed using the sum of pixel values of the fEIT images for both global and regional relative impedance change for specified regions of interest (ROIs). ROIs were determined as described by Pulletz et al. (2006), with 20% of the regression coefficient being used to determine the contour. ROIs examined were the ventral and dorsal lung regions, for analysis in supine and prone positions, and ventral, dorsal, left and right lung regions for the analysis of head position. Mean relative impedance change was used to compare ventral, dorsal and global ROIs in supine and prone positions, and the ventral, dorsal, left and right ROIs for the effect of head position.

FIGURE 1: Functional electrical impedance tomography image from a participant (aged 4–6 years) in supine position. Lighter areas represent a higher impedance change (greater ventilation) and darker areas indicate areas of a smaller impedance change (poorer ventilation).

To determine the ‘pattern’ of ventilation in both supine and prone positions, the proportion of ventilation (relative to global) was compared in the dependent and non-dependent ROI. A greater proportion of ventilation occurring in the non-dependent lung is described as a ‘paediatric pattern’, whilst a greater proportion of ventilation occurring in the dependent lung is described as an ‘adult pattern’. Where a greater proportion of ventilation was consistently distributed to the ventral or dorsal lung regions, these are further described as ‘dorsal’ or ‘ventral’ patterns, respectively.

The effect of prone and supine positions on ventilation distribution was determined with the head turned to the right in each of the positions.

Statistical analysis

Statistical analysis was performed using Statistica version 10 (StatSoft, Tulsa, USA). Data were tested for normality using the Shapiro-Wilk W-test and were found to be normally distributed. Multi-way analysis of variances (ANOVAs) were used to determine differences between age groups and ROIs in the different positions. Post hoc t-tests for dependent and independent variables were used to determine significant differences within and between groups and positions. Results are reported as means (± standard deviation) and 95% confidence interval. P-values ≤ 0.01 were considered statistically significant after applying the Bonferroni correction for multiple comparisons.

Results

Sample characteristics are presented in Table 1. Incomplete measurements were obtained in both the supine and the prone positions for three subjects and in only the prone position for one subject. Results for global and regional ventilation in different positions are presented in Table 2. Global ventilation was similar in all supine and prone positions.

TABLE 1: Sample characteristics.

TABLE 2: Mean relative impedance change (± standard deviation) as measured in different lung regions in prone and supine positions, including different head positions.

Ventral and dorsal lung regions

There was no statistical difference in ventilation within the ventral or dorsal lung regions between supine and prone positions (Table 2). However, the dorsal lung region was significantly better ventilated than the ventral lung region in both supine and prone positions (P ≤ 0.001).

Patterns followed

The majority of the participants (n = 43; 83%) consistently showed greater ventilation in the dorsal lung in both supine and prone positions, whilst two participants (4%) demonstrated greater ventilation in the ventral lung in both supine and prone positions. Five participants (10%) consistently demonstrated the paediatric pattern in both positions, whilst two (4%) consistently demonstrated the adult pattern in both positions (Table 3).

TABLE 3: Number of participants following the paediatric pattern or adult pattern in the supine or prone positions, together with a summary of the overall pattern in the two positions.

The effect of head position

There was no significant effect of head position on the distribution of ventilation within individual lung regions and between left and right, and ventral and dorsal lung regions, respectively. Global ventilation was not affected by different head positions in either supine or prone positions (Table 2).

The effect of age

There were no age-related differences in mean relative impedance change in ventral (P = 0.4) or dorsal lung regions (P = 0.7), nor globally (P = 0.8), due to body position. The effect of head position was not statistically different amongst age groups in any region in either body position.

Discussion

This study examined the distribution of ventilation in healthy, spontaneously breathing infants and children in supine and prone positions, with different head positions.

Whilst mean relative impedance change results suggest that the dorsal lung was better ventilated in both supine and prone positions, analysis of the pattern of ventilation showed that this was not the case in all participants. The previously described pattern of ventilation in the paediatric population (Davies et al. 1985; Heaf et al. 1983) is not supported by the results of this study, with ventilation distribution in the majority of participants (87%) remaining unaffected by supine or prone positioning.

A recent study in neonates (Hough et al. 2012) reported that ventilation in the dorsal lung regions was significantly higher than in the ventral lung regions in both supine and prone positions, in keeping with our results. Similar results for the supine position were found by Pham et al. (2011), who reported an increase in ventilation in the dependent (dorsal) lung in infants at 2 weeks, 3 months and 6 months of age. These findings are in line with our results in the older paediatric population; however, whether this ‘pattern’ also occurred in the prone position in infants under 6 months was not examined in the previous study (Pham et al. 2011). In another study, neonates were reported to show an equal ventilation distribution between dependent and non-dependent lung regions in both supine and prone positions (Schibler et al. 2009). In that study, measurements were taken during non-rapid eye movement sleep, during which the breathing pattern is more regular. In the present study, however, measurements were taken in awake infants and children, with an irregular breathing pattern to be expected. These differences in study conditions may account, at least in part, for the difference in results.

The distribution of ventilation in different body positions (towards the dependent lung) in the adult population has been well established and is thought to be primarily as a result of gravitational forces on the lungs (Bryan, Milic-Emili & Pengelly 1966; Gattinoni et al. 1991; Kaneko et al. 1966). Pleural pressures become increasingly more positive down the vertical axis through which gravity acts (West 2011). Consequently, the dependent lung portions have lower resting volumes and are, therefore, able to expand more during inspiration than the non-dependent portions (Frerichs, Hahn & Hellige 1996; Kaneko et al. 1966; Milic-Emili et al. 1966). Infants and children, however, have higher closing volumes and a lower functional residual capacity as a result of a more compliant chest wall and 'stiffer’ lungs (Cooper, Mellins & Mansell 1981; Davies et al. 1985; Hatch & Fletcher 1992; Heaf et al. 1983), resulting in preferential ventilation in the non-dependent lung. The disparity found between adults and children in previous studies examining ventilation distribution was explained by these differences in the respiratory mechanics as a result of a maturing respiratory system (Davies, Helms & Gordon 1992; Hatch & Fletcher 1992). Our finding, namely that there is greater ventilation in the dependent lung in the supine position, can be explained according to the effect of gravity on the distribution of ventilation seen in the adult population. In the prone position, however, it has been shown that there is a more homogenous distribution of lung tissue and alveolar inflation, as well as a smaller pleural pressure gradient, which results in a more uniform distribution of ventilation (Pelosi et al. 2002). This may account for the lack of gravity-dependent ventilation distribution seen in the prone position. Bryan et al. (1966) suggested that the distribution of ventilation depends on the magnitude of the gravitational forces acting on the lungs. As the vertical axis through which gravity acts is reduced in horizontal postures, the effect on the lung tissue may be less and may account for the similarities between supine and prone positions.

Whilst the majority of participants demonstrated a similar pattern of distribution, some participants demonstrated either a consistent adult or paediatric pattern. Variations in breathing pattern may account for the different patterns seen. It has been established in the adult population that breathing at lower lung volumes results in greater ventilation in the non-dependent lung regions (Milic-Emili et al. 1966; Schnidrig et al. 2013). Hutten et al. (2008) found that activity of the respiratory muscles varied with each breath in neonates, which may save energy whilst maintaining optimal ventilation. This fluctuating use of respiratory muscles may account for the variability in the distribution of ventilation, although further investigation is needed to test this hypothesis.

Unlike the findings of Heinrich et al. (2006), who reported significant effects of head position on the distribution of ventilation in the right lung region in a cohort of neonates, head position had no effect on the distribution of ventilation in participants (from an older paediatric population) in our study.

Lung perfusion may account for some of the impedance changes detected, as lung perfusion is affected by gravity. However, these changes are reported to account for less than 5% of the recorded impedance change (Frerichs et al. 2009).

The previously described ‘paediatric pattern’ of ventilation was not consistently observed in the present study, with the majority of participants showing consistently greater ventilation in the dorsal lung region. In clinical practice, therefore, it cannot be assumed that every infant or child preferentially ventilates the non-dependent lung. Rather, it is suggested that the selection of the position used clinically should be guided by the individual's response and preference. This response could be determined by monitoring parameters such as heart rate, respiratory rate and pattern, oxygen saturation and auscultation. Clinical use of EIT may also be valuable in determining real-time effects of positioning.

Whilst this study reveals that the distribution of ventilation in infants and children is more complex than previously thought, there are several limitations. It is recognised that ventilation distribution is affected by end-expiratory and tidal volumes (Schnidrig et al. 2013); direct measures of these may have strengthened this study. The order of positions was not randomised owing to cooperation challenges. We were, therefore, unable to determine whether the order of positioning had any effect on the distribution of ventilation. The position was difficult to standardise, given that the participants were healthy and unsedated. Lastly, participants spent only a short amount of time in each position; therefore, we were unable to determine whether distribution of ventilation is time dependent.

Despite these limitations, this study provides novel insights regarding the distribution of ventilation in healthy, spontaneously breathing infants and children in response to supine and prone positioning. In addition, it is the first to examine the effects of head position on the distribution of ventilation in an older paediatric population. This study provides baseline data against which future clinical studies can be compared. Further research is warranted to determine the effects of mechanical ventilation and respiratory disease on ventilation distribution, the effect of time spent in a specific position on ventilation distribution, and, specifically, the effect of prone turning in mechanically ventilated children with acute respiratory distress syndrome.

Acknowledgements

The authors acknowledge Tom Leenhoven (Viasys/Carefusion, Germany) for the loan of the EIT equipment and Inez Frerichs for training in EIT application. Funding was received from the Medical Research Council of South Africa, the Swiss–South African Joint Research Programme (Faculty Exchange Grant), the Department of Paediatrics and Child Health, University of Cape Town, the South African Society of Physiotherapy, and the South African National Research Foundation.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.

Authors’ contributions

A.L-S. (University of Cape Town) was responsible for the concept and study design, data collection, data analysis and interpretation, and drafting and preparing revisions of the article. A.A. (University of Cape Town), P.R. (University Hospital of Geneva) and B.M. (University of Cape Town) were responsible for the concept and study design, and contributed to data interpretation, reviewing drafts and final approval of the manuscript.

References

Bodenstein, M., David, M. & Markstaller, K., 2009, ‘Principles of electrical impedance tomography and its clinical application’, Critical Care Medicine 37, 713–724. http://dx.doi.org/10.1097/CCM.0b013e3181958d2f

Bryan, A.C., Milic-Emili, J. & Pengelly, D., 1966, ‘Effect of gravity on the distribution of pulmonary ventilation’, Journal of Applied Physiology 21(3), 778–784.

Cooper, D., Mellins, B. & Mansell, A., 1981, ‘Changes in distribution of ventilation with lung growth’, Journal of Applied Physiology 51(3), 699–705.

Curley, M.A., Hibberd, P.L., Fineman, L.D., Wypij, D., Shih, M.C., Thompson, J.E. et al., 2005, ‘Effect of prone positioning on clinical outcomes in children with acute lung injury: A randomized controlled trial’, Journal of the American Medical Association 294(2), 229–237. http://dx.doi.org/10.1001/jama.294.2.229

Davies, H., Helms, P. & Gordon, I., 1992, ‘Effect of posture on regional ventilation in children’, Pediatric Pulmonology 12, 227–232. http://dx.doi.org/10.1002/ppul.1950120406

Davies, H., Kitchman, R., Gordon, I. & Helms, P., 1985, ‘Regional ventilation in infancy’, New England Journal of Medicine 313(26), 1626–1628. http://dx.doi.org/10.1056/NEJM198512263132603

De Lema, J.B., Serrano, E., Feixas, T., Calaf, N., Camacho, M.V., Riu, P.J. et al., 2008, ‘Assessment of differential lung function by electrical impedance tomography’, Archivos de Bronconeumologia 44(8), 408–412. http://dx.doi.org/10.1016/S1579-2129(08)60072-5

Frerichs, I., Hahn, G. & Hellige, G., 1996, ‘Gravity-dependent phenomena in lung ventilation determined by functional EIT’, Physiological Measurement 17(Suppl 4A), A149–A157. http://dx.doi.org/10.1088/0967-3334/17/4A/019

Frerichs, I., Pulletz, S., Elke, G., Reifferscheid, F., Schadler, D., Scholz, J. et al., 2009, ‘Assessment of changes in distribution of lung perfusion by electrical impedance tomography’, Respiration 77(3), 282–291. http://dx.doi.org/10.1159/000193994

Frerichs, I., Schmitz, G., Pulletz, S., Schadler, D., Zick, G., Scholz, J. et al., 2007, ‘Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation’, Physiological Measurement 28(7), S261–S267. http://dx.doi.org/10.1088/0967-3334/28/7/S19

Frerichs, I., Schiffmann, H., Oehler, R., Dudykevych, T., Hahn, G., Hinz, J. et al., 2003, ‘Distribution of lung ventilation in spontaneously breathing neonates lying in different body positions’, Intensive Care Medicine 29(5), 787–794.

Gattinoni, L., Pelosi, P., Vitale, G., Pesenti, A., D'Andrea, L. & Mascheroni, D., 1991, ‘Body position changes redistribute lung computed-tomographic density in patients with acute respiratory failure’, Anesthesiology 74(1), 15–23. http://dx.doi.org/10.1097/00000542-199101000-00004

Gattinoni, L., Tognoni, G., Pesenti, A., Taccone, P., Mascheroni, D., Labarta, V. et al., 2001, ‘Effect of prone positioning on the survival of patients with acute respiratory failure’, New England Journal of Medicine 345(8), 568–573. http://dx.doi.org/10.1056/NEJMoa010043

Gillies, D., Wells, D. & Bhandari, A.P., 2012, ‘Positioning for acute respiratory distress in hospitalised infants and children’, Cochrane Database of Systematic Reviews (Online) 7, CD003645. http://dx.doi.org/10.1002/14651858.cd003645.pub3

Hatch, D. & Fletcher, M., 1992, ‘Anaesthesia and the ventilatory system in infants and young children’, British Journal of Anaesthesia 68(4), 398–410. http://dx.doi.org/10.1093/bja/68.4.398

Heaf, D., Helms, P., Gordon, I. & Turner, H., 1983, ‘Postural effects on gas exchange in infants’, New England Journal of Medicine 308(25), 1505–1508. http://dx.doi.org/10.1056/NEJM198306233082505

Heinrich, S., Schiffmann, H., Frerichs, A., Klockgether-Radke, A. & Frerichs, I., 2006, ‘Body and head position effects on regional lung ventilation in infants: An electrical impedance tomography study’, Intensive Care Medicine 32(9), 1392–1398. http://dx.doi.org/10.1007/s00134-006-0252-0

Hough, J., 2008, ‘Effect of chest physiotherapy on lung function in preterm infants’, PhD thesis, School of Health and Rehabilitation Sciences, University of Queensland.

Hough, J.L., Johnston, L., Brauer, S.G., Woodgate, P.G., Pham, T.M. & Schibler, A., 2012, ‘Effect of body position on ventilation distribution in preterm infants on continuous positive airway pressure’, Pediatric Critical Care Medicine 13(4), 446–451. http://dx.doi.org/10.1097/PCC.0b013e31822f18d9

Hutten, G.J., Van Eykern, L.A., Latzin, P., Kyburz, M., Van Aalderen, W.M. & Frey, U., 2008, ‘Relative impact of respiratory muscle activity on tidal flow and end expiratory volume in healthy neonates’, Pediatric Pulmonology 43(9), 882–891. http://dx.doi.org/10.1002/ppul.20874

Kaneko, K., Milic-Emili, J., Dolovich, M.B., Dawson, A. & Bates, D.V., 1966, ‘Regional distribution of ventilation and perfusion as a function of body position’, Journal of Applied Physiology 21(3), 767–777.

Lupton-Smith, A.R., Argent, A.C., Rimensberger, P. & Morrow, B.M., 2014, ‘Challenging a paradigm: Positional changes in ventilation distribution are highly variable in healthy infants and children’, Pediatric Pulmonology 49(8), 764–771. http://dx.doi.org/10.1002/ppul.22893

Mansell, A., Bryan, C. & Levison, H., 1972, ‘Airway closure in children’, Journal of Applied Physiology 33(6), 711–714.

Milic-Emili, J., Henderson, J., Dolovich, M., Trop, D. & Kaneko, K., 1966, ‘Regional distribution of inspired gas in the lung’, Journal of Applied Physiolology 21(3), 749–759.

Papastamelos, C., Panitch, H.B., England, S.E. & Allen, J.L., 1995, ‘Developmental changes in chest wall compliance in infancy and early childhood’, Journal of Applied Physiology 78(1), 179–184.

Pelosi, P., Brazzi, L. & Gattinoni, L., 2002, ‘Prone position in acute respiratory distress syndrome’, European Respiratory Journal 20(4), 1017–1028. http://dx.doi.org/10.1183/09031936.02.00401702

Pham, T., Yuill, M., Dakin, C. & Schibler, A., 2011, ‘Regional ventilation distribution in the first 6 months of life’, European Respiratory Journal 37(4), 919–924. http://dx.doi.org/10.1183/09031936.00034310

Pulletz, S., Van Genderingen, H.R., Schmitz, G., Zick, G., Schädler, D., Scholz, J. et al., 2006, ‘Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EIT’, Physiological Measurement 27(5), S115–S127. http://dx.doi.org/10.1088/0967-3334/27/5/S10

Reifferscheid, F., Elke, G., Pulletz, S., Gawelczyk, B., Lautenschlager, I., Steinfath, M. et al., 2011, ‘Regional ventilation distribution determined by electrical impedance tomography: Reproducibility and effects of posture and chest plane’, Respirology 16(3), 523–531. http://dx.doi.org/10.1111/j.1440-1843.2011.01929.x

Schibler, A., Yuill, M., Parsley, C., Pham, T., Gilshenan, K. & Dakin, C., 2009, ‘Regional ventilation distribution in non-sedated spontaneously breathing newborns and adults is not different’, Pediatric Pulmonology 44(9), 851–858. http://dx.doi.org/10.1002/ppul.21000

Schnidrig, S., Casaulta, C., Schibler, A. & Riedel, T., 2013, ‘Influence of end-expiratory level and tidal volume on gravitational ventilation distribution during tidal breathing in healthy adults’, European Journal of Applied Physiology 113(3), 591–598. http://dx.doi.org/10.1007/s00421-012-2469-7

Victorino, J.A., Borges, J.B., Okamoto, V.N., Matos, G.F., Tucci, M.R., Caramez, M.P. et al., 2004, ‘Imbalances in regional lung ventilation: A validation study on electrical impedance tomography’, American Journal of Respiratory and Critical Care Medicine 169(7), 791–800. http://dx.doi.org/10.1164/rccm.200301-133OC

West, J.B., 2011, Respiratory Physiology: The Essentials, 9th edn., Lippincott Williams & Wilkins, Philadelphia, PA.

Zadehkoochak, M., Blott, B.H., Hames, T.K. & George, R.F., 1992, ‘Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT (electrical impedance tomography) images’, Clinical Physics and Physiological Measurement 13(Suppl A), 191–196. http://dx.doi.org/10.1088/0143-0815/13/A/037


 